02212nas a2200217 4500000000100000008004100001260001700042100001100059700001600070700001500086700001900101700002200120700001500142700002100157700001500178245012200193300001400315490000700329520164400336022001401980 2018 d c-242712097221 aTian M1 aWu Yangfeng1 aYin Xuejun1 aFeng Xiangxian1 aPetersen Kristina1 aLi Zhifang1 aKomatsu Yuichiro1 aNeal Bruce00aSodium and potassium content of 24 h urinary collections: a comparison between field- and laboratory-based analysers. a1036-10420 v213 a

OBJECTIVE: Measurement of mean population Na and K intakes typically uses laboratory-based assays, which can add significant logistical burden and costs. A valid field-based measurement method would be a significant advance. In the current study, we used 24 h urine samples to compare estimates of Na, K and Na:K ratio based upon assays done using the field-based Horiba twin meter v. laboratory-based methods.

DESIGN: The performance of the Horiba twin meter was determined by comparing field-based estimates of mean Na and K against those obtained using laboratory-based methods. The reported 95 % limits of agreement of Bland-Altman plots were calculated based on a regression approach for non-uniform differences.

SETTING: The 24 h urine samples were collected as part of an ongoing study being done in rural China.

SUBJECTS: One hundred and sixty-six complete 24 h urine samples were qualified for estimating 24 h urinary Na and K excretion.

RESULTS: Mean Na and K excretion were estimated as 170·4 and 37·4 mmol/d, respectively, using the meter-based assays; and 193·4 and 43·8 mmol/d, respectively, using the laboratory-based assays. There was excellent relative reliability (intraclass correlation coefficient) for both Na (0·986) and K (0·986). Bland-Altman plots showed moderate-to-good agreement between the two methods.

CONCLUSIONS: Na and K intake estimations were moderately underestimated using assays based upon the Horiba twin meter. Compared with standard laboratory-based methods, the portable device was more practical and convenient.

 a1475-2727